Customer service



Customer service tel

0931-8264370

中文

Products

Electrochemical corrosion

Location:Home > Products > Electrochemical corrosion

ECT-6001 Electrochemical Ablation And Corrosion Tester

From:     Writer:  admin   Time:  2021-11-09  Click:   388

ECT-6001 Electrochemical Ablation And  Corrosion Tester, which can simulate the combined effect of erosion and cavitation of propeller, water pump, pipeline and other flow passage components in multiphase flow, provides a coupling test device with simple structure, adjustable parameters and flexible operation, which is suitable for studying the coupling effect of erosion and cavitation, coupling between mechanical factors and electrochemical factors, and coupling between material structure evolution and cavitation under the action of multiphase flow.

腐蚀冲蚀-300.png

 Key technical parameters:



1. Instrument weight:300kg

2. Appearance size:850×850×1400(mm×mm×mm)  

3. Flow velocity: 0.5~10m/s

4. Sample rotation angle:0~90°

5. Sample measurement temperature range:room temperature to 90℃

6. Friction resistance measurement range:0~100N

7. Maximum rotation speed:1000rad/min

8. Power:5kw

9. Operating Voltage:220V

10. Sample size:50×13×3、30×13×3、25×13×3、20×13×3(mm×mm×mm)

11. Data processing: the Access, Excel database file, Word experiment report and Jpeg picture can be generate

12. Electrochemical workstation test components:

Hardware specifications:

Constant potential control range of friction corrosion: ± 10V

Constant current control range of friction corrosion: ± 200mA

Control accuracy of friction corrosion potential: 0.1% × Full scale reading ± 1mV

Control accuracy of friction corrosion current: 0.1% × Full scale reading

Friction corrosion potential resolution: 10uV (>100Hz), 3uV (<10Hz)

Friction corrosion current sensitivity: 1pA

Friction corrosion current range: 2nA~200mA, 9gears in total

Friction corrosion tank pressure: ± 13V

Maximum output current of friction corrosion: 200mA

Frequency response of friction corrosion impedance: 10uHz~1MHz

Functions of electrochemical corrosion software:

Open circuit potential test (OCP), potentiostatic polarization, constant current polarization, linear cyclic voltammetry (CV), linear scanning voltammetry (LSV), square wave voltammetry (SWV), polarization curve test (Tafel), battery charge discharge test (GCD), impedance test potential/current control mode, constant frequency impedance test potential/current control mode, Motschottky curve test;

The software supports the serialization test function, and can realize automatic measurement under unattended condition through user-defined method combination;