GFT-150 Gear (Spline) Tribometer

From:  Huahui Instrument   Writer:  admin   Time:  2022-04-28  Click:   287

The gear (spline) Tribometer is mainly used to measure the friction and wear characteristics of spline pair with inclination misalignment under certain temperature and lubrication conditions, and study the relationship between spline wear and lubrication, misalignment, torque, vibration, temperature and other factors.

整机-1.png

Key technical parameters

1. Instrument weight1500kg

2. Appearance size:2700×750×1450mm×mm×mm

3. Power:50kw

4. Operating Voltage:380V

5.  inclination angle of spline pair: 0~40 points (increment: 5 points)

6. Rotation speed: 1~1000 r/min

7. Test temperature: room temperature~200℃ 

8. Torque measurement:0~150Nm

9. Spline lubrication method: oil injection lubrication

10. Dimension of spline sleeve: the maximum outer diameter is 85mm

11. Data processing:the Access, Excel database file, Word experiment report and Jpeg picture can be generated